Configuring Plant Data

19�5 Defining the Feed-in tariff

The feed-in tariff is generally used to calculate a PV plant's output in financial terms.

Considering that self-consumption is used at more and more plants, there are also other calculation modes.

General

The plant costs are set in euros in the

General

menu. This value is used for the

Diagnostic | Finances

func-

tion.

The Yield offsets field is used to manually add the plant's previously yields,

e.g. in cases when the plant was already operational before having a monitoring system installed. These

yields are included in the

yield forecast.

Note

When using several plant groups, only one plant group can be used with a tariff mode

with self-consumption refund or self-consumption.

Tariff settings

The Solar-Log™ provides four different modes:

Feed-in tariff

Feed-in tariff + Self-consumption refund

Feed-in tariff + Self-consumption

Consumption of Self-produced power

Feed-in tariff mode

All of the power output from the PV plant is completely fed into the grid. Every kilowatt hour is reimbursed

according to the valid remuneration rate.

In this mode, the

From date

and the corresponding

rate

in cents for the feed-in tariff need to be defined.

The Solar-Log™ calculates the amount of power fed into the grid based on the inverter information.

Feed-in tariff + Self-consumption refund mode

Here a distinction is made between generated power that is fed into the grid and that is directly consumed

(self-consumption). In accordance with feed-in tariff agreements (or renewable energy laws), a bonus is

paid for self-consumption. This provides a financial incentive for self-consumption. To implement this func-

tion, the Solar-Log™ requires an additional consumption meter.

In this mode, the

From date

and the corresponding

rate

in cents for the feed-in tariff and self-consump-

tion refund need to be defined. The electricity prices are entered in an extra tab. The Solar-Log™ calculates

the amount of power fed into the grid based on the inverter information.

Feed-in tariff + Self-consumption mode

In this mode, only the fed-in power is reimbursed. There is still an incentive for self-consumption because

generally the costs for power obtained from the gird are higher than the production costs of self-produced

power.

To implement this function, the Solar-Log™ requires an additional consumption meter.

In this mode, the

From date

and the corresponding

rate

for the feed-in tariff need to be defined. The

electricity prices are entered in an extra tab. The Solar-Log™ calculates the amount of power fed into the

grid based on the inverter information.