Connector Assignments and Wiring

10�4 RS485/422 - C (only Solar-Log 2000)

Use the provided terminal block connectors when connecting inverters or accessories to the RS485/422 C

interface.

Fig.: 6-pin Terminal block connector

RS485/422 C

PIN

Assignments RS485

Assignments RS422

1

Data +

T/RX+

2

12 V

12V

3

Ground

Ground

4

Data -

T/RX-

5

R/TX+

6

R/TX-

Note

If inverters that use the RS422 connection are connected to this
nterface (e.g. Fronius, AEG, Riello), then it is not possible to connect accessories such as
sensors, meters or displays to this bus.