20�4 alarm, Only solar-log 1000 and 2000) – Solare Datensysteme Solar-Log User Manual

Page 111

Advertising
background image

111

Configuring Notifications

20�4 Alarm

(only Solar-Log 1000 and 2000)

The Solar-Log™ continuously monitors its internal alarm contact. If this contact is opened, it sets off an

alarm which can be indicated in various ways. In the

Alarm

tab, the alarm contact can be activated and

different types of notification can be configured.

Activating alarm contact
Procedure:

Select

Configuration | Plant | Plant groups

from the menu.

Activate the

Activate Alarm Contact

button.

SAVE

settings.

After activating alarm notifications, a triggered alarm can be indicated by:

E-mail

Text message (SMS)

Relay

Speaker

.

The e-mail and text message (SMS) settings must be pre-configured.

Procedure

Activate

the desired

Notifications

.

SAVE

settings.

Test section

Here you have the option to perform an alarm test.

20�5 Power & Failure

Performance monitoring is based on a comparison of the power out from all of the inverters, including

individual trackers in the case of inverters with more than one tracker or, as the case may be, sensors. If

the target power deviates from the actual power by more than a certain tolerance (= min. feed-in power),

a notification can be sent by e-mail and/or text message (SMS) after the selected fault duration has been

reached.

If an individual module loses power, the string power for the same level of irradiation will drop, and can

thus be detected and reported.

Power comparison always works reliably, even if the weather is cloudy. The important thing is that all mod-

ules should not be overshadowed. Therefore, the monitoring period should be scheduled for periods when

there are no shadows.

As power measurement in the inverter is very inaccurate under a certain threshold, a minimum percentage

value can also be specified below which monitoring is interrupted.

Procedure

Select the device that is to be monitored

Select the Performance Monitoring mode.
Select per MPP tracker or for the total of all of the MPP trackers. There is also the option to deacti-
vate the performance monitoring.

Set the monitoring parameters

Enter the monitoring begin