ProSoft Technology MVI46-MCM User Manual

Page 91

Advertising
background image

MVI46-MCM ♦ SLC Platform

Reference

Modbus Communication Module

User Manual

ProSoft Technology, Inc.

Page 91 of 108

March 29, 2011

Example and State Diagram
Here is an example of a request to remote device to Return Query Data. This
uses a sub-function code of zero (00 00 hex in the two-byte field). The data to be
returned is sent in the two-byte data field (A5 37 hex).

Request

Response

Field Name

(Hex)

Field Name

(Hex)

Function 08

Function 08

Sub-function Hi

00

Sub-function Hi

00

Sub-function Lo

00

Sub-function Lo

00

Data Hi

A5

Data Hi

A5

Data Lo

37

Data Lo

27

The data fields in responses to other kinds of queries could contain error counts
or other data requested by the sub-function code.

Advertising