Ap-11 – Furuno GP-150-DUAL User Manual

Page 101

Advertising
background image

APPENDEX

AP-11

Load Requirements

Isolation: opto coupler
Input Impedance: 470

Max. Voltage:

±

15V

Threshold: 3mA (In case of FURUNO device talker connection)

"DATA3" Port

20P8192

MJ-A6SRMD

14

13

12

2

2

1

1

DATA3

1

J6

2

3

4

5

6

FL15

FL14

JP4

TD-A

TD-B

U25
SN75ALS172

JP3

Output Drive Capability

Max. 10mA