10. INSTALLATION

10-7

How to attach the N-P-8DFB connector

Outer Sheath

Armor

Inner Sheath Shield

Remove outer sheath and armor by the
dimensions shown left.
Expose inner sheath and shield by the
dimensions shown left.

Cut off insulator and core by 10mm.

Twist shield end.

Slip on clamp nut, gasket and clamp as
shown left.

Fold back shield over clamp and trim.

Cut aluminum foil at four places, 90

°

from one another.

Fold back aluminum foil onto shield and
trim.

Expose the insulator by 1mm.

Expose the core by 5mm.

Slip the pin onto the conductor. Solder
them together through the hole on the
pin.

Insert the shell into the pin. Screw the
clamp nut into the shell.
(Tighten by turning the clamp nut. Do
not tighten by turning the shell.)

Cover with heat-shrink tubing and heat.

30

10

Clamp

Nut

Gasket

(reddish

brown)

Clamp

Aluminum Foil

Trim shield here.

Trim aluminum

tape foil here.

Insulator

1

5

Clamp Nut

Pin

Shell

Solder through
the hole.

50

30