Connections – Furuno GP-150-DUAL User Manual

Page 88

Advertising
background image

10. INSTALLATION

10-20

Grounding
To prevent electrical shock and mutual interference, run a ground wire between

the earth terminal on the unit and ship’s superstructure.

Cabling schedules
The signal cable should be a twisted-pair, double-screened cable. Ground the

signal cable at the cable clamp.

Connections

Power supply
J1 (24 VDC)

Pin no.

Designation

#1 +
#2 -

Input signal (NMEA)
The signal from GPS navigator is connected to J2 and J3. Data being fed to J2

has higher priority than J3.

J2 J3

Pin no.

Designation

Pin no.

Designation

#3

RD1-H #3 RD2-H

#4

RD1-C #4 RD2-C

#6

GND #6 GND

Output signal (RS-422 or NMEA)
J4, J5, J6, J7, J8, J9

Pin no.

RS-422

NMEA

#1 TD-B TD-H
#2 TD-A TD-C

#4* GND GND

*#5 for J9

Advertising