10. INSTALLATION

10-2

10.2 Display

Unit

The display unit can be installed using either of four methods as shown below.

Refer to the outline drawing page D-1, D-2, and D-3.


• Locate the unit away from exhaust pipes and vents.
• The mounting location should be well ventilated.
• Mount the unit where shock and vibration are minimal.
• Keep the display unit away from electromagnetic field generating equipment

such as motor, generator.

• Allow sufficient maintenance space and a sufficient slack in cables for

maintenance and repair.

Table Top and Overhead Mounting

TABLE TOP

OVERHEAD

Figure 10-2 Display unit mounting methods

Flush mounting type F
An optional flush mount kit type F is required. For details, see outline drawing

page D-3. (Name: Flush Mount Kit F, Type: OP20-25, Code No.: 004-393-280)

Name Type

Code

No.

Qty

Self-tapping screw

5X20

000-802-840

4

Hex. bolt

M6X12 SUS304

000-862-127

2

Spring washer

M6 SUS304

000-864-260

2

Cosmetic panel

20-013-1121

100-234-240

1