6 interface unit if-2500, Specifications, Installation – Furuno GP-150-DUAL User Manual

Page 86

Advertising
background image

10. INSTALLATION

10-18

10.6 Interface Unit IF-2500

Specifications

Input port

2 ports for NMEA 0183 data

Output port

6 ports for either of NMEA 0183 or RS-422 data

3 ports for alarm signal

Power supply 10 to 35 VDC

Power consumption 2.2 W maximum

Color

2.5G5/1.5 Newtone no. 5

Ambient temperature -15°C to +55°C

Humidity

Relative humidity 95% at +40°C

Waterproofing None

Installation

Mounting considersations
The installation site is important for

proper operation and continued

performance. Select it keeping the

following points in mind.

The unit is not waterproof; locate

it away from water spray.

Select a clean and cool place.

Select a place where

shock,vibration and electrical noise

are minimal.

Leave sufficient space at the sides

and rear of the unit for

maintenance and service.

Mounting
The unit can be mounted on a

bulkhead, overhead or tabletop.

Secure the unit to mounting

location with woodscrews. For

added support, use nuts, bolts and

washers instead of woodscrews.

Cable fabrication
1) Remove the outer sheath, armor, and shield as illustrated.

2) Remove the insulation of cores 3 mm.

3) Cut and solder unused cores to the shield.

• All dimensions in
millimeters.
• For added support, use
nuts, bolts and washers
instead of woodscrews.
• Leave sufficient space
at the sides and rear of
the unit for maintenance
and servicing.

Interface unit mounting
di

i

Advertising