9 apportioning the memory, 10 bearing reference – Furuno GP-150-DUAL User Manual

Page 21

Advertising
background image

2. DISPLAY AND TRACK


2-5

2.9 Apportioning

the

Memory

The memory holds 2,000 points of track and
marks and may be apportioned as you like.
The default memory setting stores 1,000
points each of track and marks.

Note: All data are erased when the memory

apportion setting is changed, even
when the previous value is reentered.


To store 1,500 points of track and 500 marks,
for example, do the following:

1) Press the

MENU ESC key.

2) Press

9 to display the SYSTEM

SETTINGS menu.

2. UNIT SETUP

SYSTEM SETTINGS

1. PLOTTER SETUP
2. UNIT SETUP
3. DATA 1, 3 OUTPUT SETUP
4. DATA TRANSFER
5. DATA 4 I/O SETUP
6. GPS SETUP
7. DGPS SETUP
8. LOP SETUP
9. CLEAR MEMORY

2. UNIT SETUP

ENT: Enter

MENU: Escape

Figure 2-8 SYSTEM SETTNGS menu


3) Press

1 to display the PLOTTER SETUP

menu.

PLOTTER SETUP

Bearing Ref.

Auto

(07

°

W)

Man

(00

°

E)

ENT: Enter

MENU: Escape

Memory Apportion

Mag Variation

True

Trk = 1000 / 2000Pt

Mag

R.L

G.C

Calculation

User defined #1

RNG

User defined #2

SOG

User defined #3

BRG

User defined #4

COG

Figure 2-9 PLOTTER SETUP menu

4) Press to select Memory Apportion.
5) Enter amount of track to store, in four

digits. To store 1,500 track points, for
example, press

1, 5, 0, 0.

6) Press the

NU/CU ENT key, or or .

You are asked if it is all right to erase all
data.

Setting erases all data!

Are you sure to change ?

ENT: Yes MENU: No

Figure 2-10


7) Press the

NU/CU ENT key.

8) Press the

MENU ESC key.

Note: Two display units in a system should

be set the same points for memory
setting store to share waypoints data.

2.10 Bearing Reference

Ship's course and bearing to waypoint may
be displayed in true or magnetic bearing.
Magnetic bearing is true bearing plus (or
minus) earth's magnetic deviation.

True or magnetic bearing

The default setting displays true bearings.

1) Press the

MENU ESC key.

2) Press

9 to display the SYSTEM

SETTINGS menu.

3) Press

1 to display the PLOTTER SETUP

menu.

4) Press or to select Bearing Ref.
5) Press or to select True or Mag.
6) Press the

NU/CU ENT key.

7) Press the

MENU ESC key.


Advertising