10. INSTALLATION

10-16

Setting DATA 4 to "COM." (general data)

Waypoint data can be received from a personal computer, through the DATA 4

port. Note that the data transmitting operation should be done after receiving

data using DATA 4 port. For details, see page 1-6.

1) Press

MENU ESC, 9 and 5.

2) Press to select Level.

3) Press or to select level of personal computer; RS232C or RS422.

4) Press the

CU/NU ENT key.

5) Press or to select Com.

6) Press to select To Next Page. The DATA 4 I/O SETUP <Com.> menu

appears.

Loading erases current data
Are you sure to load?

ENT: Yes MENU: No

I/O SETUP <Com.> menu

7) Press to select Baud Rate.

8) Press or to select baud rate; 4800bps, 9600bps, or 19200bps.

9) Press the

CU/NU ENT key.

10) Press to select WPT/RTE.

11) Press to select Command. Stop, on the same line as Command, appears

in reverse video.

12) Press to select Start. The message shown in below appears.

Now loading
WPT/RTE data !

MENU: Stop

13) Press the

CU/NU ENT key. The message shown in below appears while data

is being loaded.

Are you sure to stop ?

ENT: Yes MENU: No

14) Output data from the computer. When data is loaded, the cursor shifts to

Stop.

15) Press the

ESC key.