13 data1 output setting – Furuno GP-150-DUAL User Manual

Page 81

Advertising
background image

10. INSTALLATION

10-13

DATA1 output setting

1) Press

MENU ESC, 9 and 3 keys to show the DATA1, 3 OUTPUT SETUP

menu.

Talker ID

GP

LC

DE

Output Data (00-90 sec) 82%

1. AAM:00 APA:00

APB:04 BOD:00

2. BWC:00 BWW:00 GGA:01 GLL:01
3. RMB:01 RMC:00 VTG:01 WCV:00
4. VDR:00 WPL:00 XTE:00 ZDA:01
5. GNS:00 GBS:01 Rnn:00 RTE:00

DATA3. Log Pulse

400ppm

DATA 1, 3 OUTPUT SETUP

MENU : Escape

ENT : Enter

200ppm

Settings shown above are default settings.

This line appears only when LOG is
selected by internal jumper blocks.

Data Fmt.

V1.5

IEC

TX rate of operation

V2.0

DATA1, 3 OUTPUT SETUP menu

2) Press to select DATA FMT.

3) Press or to select V1.5, V2.0 or IEC.

4) Press the

CU/NU ENT key. Talker ID appears in reverse video.

5) Press or to select GP, LC or DE.

6) Press the

CU/NU ENT key.

7) Enter TX interval for each output data sentence in line 1. TX interval is

available in 00, 01, 02, 03, 04, 05, 06, 10. 15, 20. 30, 60 and 90 msec.

8) Press the

MENU ENT key.

9) Enter TX interval for each output data sentence in lines 2 through 5. Press

the

CU/NUENT key after setting each line.

In great circle calculation, BWC and WNC are output but BWR and WNR are not.

In rhumb line navigation, BWR and WNR are output but BWC and WNC are not.

The total data output are shown by percentage on the third line.

For best results the total output should be less than 90%; lengthen the Tx

interval of less important data to make the total output less than 90%.