Multi-Tech Systems MULTIVOIP MVP-410ST/810ST User Manual

Page 159

Advertising
background image

MultiVOIP User Guide

Technical Configuration (T1/E1)

159

T1 Parameter Definitions (cont’d)

Field Name

Values

Description

Line Build Out 0 dB, -7.5 dB,

-15 dB, -22.5 dB

To reduce the crosstalk on
received signals, a transmit
attenuator can be placed in the
data path. Transmit attenuation
is selectable. Default: O dB

Pulse Shape
Level

0 to 40 Meters
40 to 81 m
81 to 122 m
122 to 162 m
162 to 200 m

Refers to length of cable
between MultiVOIP and
PBX/telco in meters. Most
common will be 0 to 40m.

Clocking

External/Internal Set opposite to telco/PBX

setting. Example: if telco
clocking internal, set VOIP
clocking as external.

Line Coding

AMI / B8ZS

Match to PBX or telco.

PCM Law

A-Law/Mu-Law

Match to PBX or telco. “
Mu-law” is analog-to-digital
compression/expansion
standard used in North
America. “A-law” is European
standard.

Yellow Alarm
Format

Bit 2 / 1111…

Depending on the Frame
Format used, there are choices
of Yellow Alarm format, as
follows:

D4

: -Bit2 = 0 in every speech

channel
-FS

bit of frame 12 is forced

to one.

ESF

: -Bit2 = 0 in every speech

channel
–1111111100000000

pattern

in data link channel.

Check with your PBX/telco
administrator for the correct
setting or use the default value
(1111 … ).