background image

Technical Configuration (T1/E1)

MultiVOIP User Guide

174

“Regional Parameter” Definitions (cont’d)

Field Name

Values

Description

Cadence
(msec) On/Off

n/n/n/n
four integer time
values in
milli-seconds;
zero value for
dial-tone
indicates
continuous tone

On/off pattern of tone durations
used to denote phone ringing,
phone busy, connection
unobtainable (fast busy), and dial
tone (continuous and described as
“0“). Default values differ for
different countries/regions.
Although most cadences have only
two parts (an “on” duration and
an “off” duration), some telephony
cadences have four parts. Most
cadences, then, are expressed as
two iterations of a two-part
sequence. Although this is
redundant, it is necessary to allow
for expression of 4-part cadences.

Custom
(button)

--

Click on the “Custom” button to
bring up the Custom Tone Pair
Settings

screen. This screen allows

the user to specify tone pair
attributes that are not found in any
of the standard national/regional
telephony toning schemes.

Country
Selection for
Built-In
Modem

country name

MultiVOIP units operating with
the X.06 software release (and
above) include a built-in modem.
The administrator can dial into this
modem to configure the MultiVOIP
unit remotely. The country name
values in this field set telephony
parameters that allow the modem
to work in the listed country. This
value may be different than the
Country/Region value. For
example, a user may need to
choose “Europe” as the
Country/Region value but
“Denmark” as the Country-
Selection-for-Built-In-Modem
value.