Multi-Tech Systems MULTIVOIP MVP-410ST/810ST User Manual

Page 249

Advertising
background image

MultiVOIP User Guide

Technical Configuration (Analog/BRI)

249

FXO Interface: Parameter Definitions (cont’d)

Field Name

Values

Description

Dialing Options (cont’d)

Inter Digit
Regeneration
Time

50 to 20,000
milliseconds

The length of time between the
outputting of DTMF digits.
Default = 100 ms.

FXO Disconnect On

There are three possible criteria
for disconnection under FXO:
current loss, tone detection, and
silence detection.
Disconnection can be triggered
by more than one of the three
criteria.

Current Loss

Y/N

Disconnection to be triggered
by loss of current. That is,
when Current Loss is enabled
(“Y”), the MultiVOIP will hang
up the call when it detects a loss
of current initiated by the
attached device.

Current Loss
Detect Timer

integer values
(in milliseconds )

The minimum time required for
detecting the current loss signal
on the FXO interface. In other
words, this is the minimum
length of time the current must
be absent to validate ‘current
loss’ as a disconnection
criterion. Default = 500 ms.

Tone Detection

Y/N

Disconnection to be triggered
by a tone sequence.

Advertising