Repair procedures - efcm basic edition, Obtain log information, Repair procedures - efcm basic edition -9 – McDATA 4300 User Manual

Page 111: Obtain log information -9

Advertising
background image

Repair Information

4-9

Repair Information

Repair Procedures - EFCM Basic Edition

The following procedures (performed at a PC communicating with
the EFCM Basic Edition interface) are described:

Obtain log information.

Perform port diagnostics.

Collect maintenance data.

Set online state.

Block or unblock a port.

Upgrade firmware.

Manage configuration data.

Obtain Log
Information

The EFCM Basic Edition interface provides access to logs that contain
maintenance information. Select the desired log from the Logs menu
at any view. Logs with maintenance information are:

Event.

Link Incident.

Open Trunking Re-Route.

Fabric.

Embedded Port Frame.

Port Failure

Off

On

Red and Yellow
Blinking Diamond

Port failed and requires service.

Segmented
E_Port

On

Off

Yellow Triangle

E_Port segmented, preventing connected switches from
forming a fabric. Reason appears as supplementary data in
the Event Log.

Testing

Off

On

Blinking

Blinking

Yellow Triangle

Yellow Triangle

Port is performing an internal loopback test.

Port is performing an external loopback test.

Table 4-1

Port Operational States (Continued)

Port

State

Blue/Green

LED

Amber

LED

Alert

Symbol

Description

Advertising