Event Code: 400

Message:

Power-up diagnostics failure.

Severity:

Major.

Explanation:

Power-on self tests (POSTs) detected a failed FRU as indicated by the event data.

Action:

If a CTP card, fan, or power supply failure is indicated, replace the switch. Perform a data collection and return
the CD to support personnel.

Event Data:

Byte 0 = FRU code as follows: 02 = CTP card, 05 = cooling fan, 06 = power supply assembly.
Byte 1 = FRU slot number.

Distribution:

Product

Management Server

Host

EFCM Basic

Event Log

System

Error LED

Event Log

E-Mail

Call-Home

Sense Info

Link Incident

Log

Event Code: 410

Message:

Switch reset.

Severity:

Informational.

Explanation:

The switch reset due to system power-up, IML, or manual reset. A software reset can occur automatically after a
firmware fault (event code 411), or be user-initiated. Event data indicates the type of reset.

Action:

No action required.

Event Data:

Byte 0 = reset type as follows: 00 = power-on, 02 = IML, 04 = reset.

Distribution:

Product

Management Server

Host

EFCM Basic

Event Log

System

Error LED

Event Log

E-Mail

Call-Home

Sense Info

Link Incident

Log