Removal and Replacement Procedures

5-5

Removal and Replacement Procedures

4. Perform an external loopback test. Refer to

External Loopback Test

for instructions. If the test fails, go to

MAP 0000: Start MAP

to

isolate the problem.

5. Reconnect the fiber-optic jumper cable:

a. Remove the protective cap from the cable connector and the

protective plug from the port optical transceiver. Store the cap
and plug in a suitable location for safekeeping.

b. Clean the jumper cable and transceiver connectors. Refer to

Clean Fiber-Optic Components

for instructions.

c. Insert the keyed LC cable connector into the port’s optical

transceiver.

6. Ensure the amber port LED extinguishes. If the LED illuminates,

go to

MAP 0000: Start MAP

to isolate the problem.

7. At a web browser communicating with the EFCM Basic Edition

interface, select Event from the Logs menu. Ensure an event code
510

(SFP optics hot-insertion initiated) appears. If the event code

does not appear, go to

MAP 0000: Start MAP

to isolate the

problem.

8. At a web browser communicating with the EFCM Basic Edition

interface, open the Hardware View and verify port operation:

a. Ensure alert symbols do not appear (yellow triangle or red

diamond).

b. Open the Port List View. Verify that port Operational State, Type,

Health Status, and Transceiver are correct.

If a problem is indicated, go to

MAP 0000: Start MAP

to isolate the

problem.

9. Restore communication to the port as directed by the customer.

Refer to

Block or Unblock a Port

for instructions. Inform the customer

the port is available.

10. Clear the system error LED on the product front bezel. At a web

browser communicating with the EFCM Basic Edition interface,
select Clear System Error Light from the Maintenance menu.

11. If necessary, close and lock the equipment cabinet door.