General Information

1-7

General Information

Storage and Shipping

Environment

Protective packaging must be provided to protect the switch under
all shipping methods (domestic and international).

Shipping temperature:

-40

0

F to 140

0

F (-40

0

C to 60

0

C)

Storage temperature:

34

0

F to 140

0

F (1

0

C to 60

0

C)

Shipping relative humidity:

5% to 100%

Storage relative humidity:

5% to 80%

Maximum wet-bulb temperature:

84

0

F (29

0

C)

Altitude:

40,000 feet (12,192 meters)

Operating

Environment

Temperature:

40

0

F to 104

0

F (4

0

C to 40

0

C)

Relative humidity:

8% to 80%

Maximum wet-bulb temperature:

81

0

F (27

0

C)

Altitude:

10,000 feet (3,048 meters)

Maintenance Approach

The maintenance approach instructs service personnel to perform
fault isolation and repair procedures without degrading or
interrupting product operation or associated applications. Fault
isolation begins when one or more of the following occur: