Step 2, Step 3, Step 4 – McDATA 4300 User Manual

Page 92: Step 5

Advertising
background image

3-28

McDATA Sphereon 4300 Fabric Switch Installation and Service Manual

Maintenence Analysis Procedures

2

A minor error occurred that caused the Fabric Services database to
be re-initialized to an empty state, and a disruptive fabric logout and
login occurred for all attached devices. Indications are:

Event code 011 - The Login Server database failed cyclic
redundancy check (CRC) validation.

Event code 021 - The Name Server database failed CRC
validation.

Devices resume operation after fabric login. Perform a data collection
and contact the next level of support. Refer to

Collect Maintenance

Data

. Exit MAP.

3

As indicated by event code 051, a minor error occurred that caused
the Management Server database to be re-initialized to an empty
state and fail CRC validation. A disruptive server logout and login
occurred for all attached devices.

Devices resume operation after Management Server login. Perform a
data collection and contact the next level of support. Refer to

Collect

Maintenance Data

. Exit MAP.

4

As indicated by event code 061, a minor error occurred that caused
the Fabric Controller database to be re-initialized to an empty state
and fail CRC validation. The product briefly lost interswitch link
capability.

Interswitch links resume operation after CTP reset. Perform a data
collection and contact the next level of support. Refer to

Collect

Maintenance Data

. Exit MAP.

5

As indicated by event code 062, Fabric Controller software detected a
path to another fabric element (director or switch) that traverses more
than three interswitch links (hops). Fibre Channel frames may persist
in the fabric longer than timeout values allow.

Advise the customer of the problem and reconfigure the fabric so the
path between any two fabric elements does not traverse more than
three hops.