background image

Event Code Tables

A-21

Event Code Tables

Fan Events (300 through 399)

Event Code: 300

Message:

Cooling fan propeller failed.

Severity:

Major.

Explanation:

One cooling fan failed or is rotating at insufficient angular velocity.

Action:

Replace the switch.

Event Data:

The first byte of event data (byte 0) specifies the failed fan number.

Distribution:

Product

Management Server

Host

EFCM Basic

Event Log

System

Error LED

Event Log

E-Mail

Call-Home

Sense Info

Link Incident

Log

Event Code: 301

Message:

Cooling fan propeller failed.

Severity:

Major.

Explanation:

Two cooling fans failed or are rotating at insufficient angular velocity.

Action:

Replace the switch.

Event Data:

The first byte of event data (byte 0) specifies the failed fan number(s).