McDATA 4300 User Manual

Page 175

Advertising
background image

Event Code Tables

A-35

Event Code Tables

Event Code: 516

Message:

Optical digital diagnostics alarm threshold exceeded.

Severity:

Minor.

Explanation:

An optical transceiver digital diagnostics alarm threshold was exceeded. Additional event code 516 events are
recorded if the problem persists.

Action:

Replace the transceiver.

Event Data:

Byte 0 = port number.
Byte 2 = optic type.
Bytes 4 - 7 = elapsed millisecond tick count.
Bytes 8 - 31 = First, second, and third type (and threshold value) of warning threshold exceeded as follows:
01 = TX temperature, 02 = TX supply voltage, 03 = TX bias current, 04 = TX power, 05 = RX power.

Distribution:

Product

Management Server

Host

EFCM Basic

Event Log

System

Error LED

Event Log

E-Mail

Call-Home

Sense Info

Link Incident

Log

Event Code: 523

Message:

FL_Port open request failed.

Severity:

Informational.

Explanation:

When the indicated FL_Port attempted to open a loop device, a port open (OPN) sequence was returned.

Action:

No action required.

Event Data:

Byte 0 = port number.
Byte 1 = arbitrated loop physical address (AL_PA) of the device transmitting the OPN sequence.

Distribution:

Product

Management Server

Host

EFCM Basic

Event Log

System

Error LED

Event Log

E-Mail

Call-Home

Sense Info

Link Incident

Log

Advertising