3-4

McDATA Sphereon 4300 Fabric Switch Installation and Service Manual

Maintenence Analysis Procedures

410

Switch reset.

No action required.

411

Firmware fault.

Go to

MAP 0200

.

412

CTP watchdog timer reset.

Go to

Collect Maintenance Data

.

421

Firmware download complete.

No action required.

423

CTP firmware download initiated.

No action required.

426

Multiple ECC single-bit errors occurred.

Go to

MAP 0400

.

433

Non-recoverable Ethernet fault.

Go to

MAP 0400

.

440

Embedded port hardware failed.

Go to

MAP 0400

.

442

Embedded port anomaly detected.

No action required.

445

ASIC detected a system anomaly.

No action required.

453

New feature key installed.

No action required.

506

Fibre Channel port failure.

Go to

MAP 0500

.

507

Loopback diagnostics port failure.

Go to

MAP 0500

.

508

Fibre Channel port anomaly detected.

No action required.

510

Optical transceiver hot-insertion initiated.

No action required.

512

Optical transceiver nonfatal error.

Go to

MAP 0500

.

513

Optical transceiver hot-removal completed.

No action required.

514

Optical transceiver failure.

Go to

MAP 0500

515

Optical digital diagnostics warning threshold exceeded.

Go to

MAP 0500

.

516

Optical digital diagnostics alarm threshold exceeded.

Go to

MAP 0500

.

523

FL_Port open request failed.

No action required.

524

No AL_PA acquired.

No action required.

525

FL_Port arbitration timeout.

No action required.

581

Implicit incident.

Go to

MAP 0500

.

582

Bit error threshold exceeded.

Go to

MAP 0500

.

Table 3-3