Maintenance Analysis Procedures

3-31

Maintenence Analysis Procedures

9

An E_Port segmented because two fabric elements had duplicate
domain IDs.

a. Determine the desired domain ID (1 through 31 inclusive) for

each product.

b. Inform the customer both products will be set offline. Ensure the

system administrator quiesces Fibre Channel frame traffic and
sets attached devices offline.

c. Set both products offline. Refer to

Set Online State

.

d. Select Switch and Parameters from the Configure menu at any

view. The Parameters View displays.

e. Type the customer-determined preferred domain ID value, then

click OK or Activate.

f. Repeat steps d and e at the second product (attached to the

segmented E_Port). Use a different preferred domain ID value.

g. Set both products online. Refer to

Set Online State

.

Was the maintenance action successful?

NO

YES

The fabric, ISL, and product are operational. Exit MAP.

Contact the next level of support. Exit MAP.

10

An E_Port segmented because two products had incompatible zoning
configurations. An identical zone name is recognized in the active
zone set for both products, but the zones contain different members.

a. Determine the desired zone name change for one of the affected

products. Zone names must conform to the following rules:

— The name must be 64 characters or fewer in length.

— The first character must be a letter (a through z), upper or

lower case.

— Other characters must be alphanumeric (a through z

or 0 through 9), dollar sign ($), hyphen (-), caret (^), or
underscore (_).