Esd procedures, Field-replaceable units, Esd procedures -2 field-replaceable units -2 – McDATA 4300 User Manual

Page 130: Concurrent fru -2

Advertising
background image

5-2

McDATA Sphereon 4300 Fabric Switch Installation and Service Manual

Removal and Replacement Procedures

ESD Procedures

Follow these ESD procedures:

If the product is connected to facility power (grounded), wear an
ESD wrist strap and grounding cable connected to the product
chassis.

If the product is not connected to facility power (not grounded),
wear an ESD wrist strap and grounding cable connected to an
approved bench grounding point.

Touch the product chassis once before performing a procedure,
and once each minute during the procedure.

Store ESD-sensitive FRUs in antistatic packaging.

Field-Replaceable Units

Table 5-1

lists the concurrent FRU that is removed and replaced while

the product is powered on and operational. The table also lists ESD
precautions (yes or no) for the FRU, and references the RRP page
number. Refer to

Chapter 6

,

Illustrated Parts Breakdown

for FRU

locations and part numbers.

Table 5-1

Concurrent FRU

Concurrent FRU

ESD Requirement

Page

Small form factor pluggable optical transceiver

Yes

5-3