McDATA 4300 User Manual

Page 179

Advertising
background image

Event Code Tables

A-39

Event Code Tables

Event Code: 585

Message:

Primitive sequence timeout.

Severity:

Major.

Explanation:

An attached server recognized either a link reset (LR) protocol timeout or a timeout while waiting for the
appropriate response (while in a NOS receive state and after NOS was not longer recognized).

Action:

A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI).
If fault isolation at the server does not detect a failure, the problem may be due to a port failure. Go to

MAP 0000:

Start MAP

to perform fault isolation. In addition, perform a data collection and return the CD to support personnel.

Event Data:

Refer to the T11/99-017v0 document for the specific link incident record format.

Distribution:

Product

Management Server

Host

EFCM Basic

Event Log

System

Error LED

Event Log

E-Mail

Call-Home

Sense Info

Link Incident

Log

Event Code: 586

Message:

Invalid primitive sequence received for current link state.

Severity:

Major.

Explanation:

An attached server recognized either a link reset (LR) or a link-reset response (LRR) sequence while in the
wait-for-online sequence (OLS) state.

Action:

A LIR is generated and sent to the attached server using the reporting procedure defined in T11/99-017v0 (OSI).
If fault isolation at the server does not detect a failure, the problem may be due to a port failure. Go to

MAP 0000:

Start MAP

to perform fault isolation. In addition, perform a data collection and return the CD to support personnel.

Event Data:

Refer to the T11/99-017v0 document for the specific link incident record format.

Distribution:

Product

Management Server

Host

EFCM Basic

Event Log

System

Error LED

Event Log

E-Mail

Call-Home

Sense Info

Link Incident

Log

Advertising