Go to, Step 6, O to – McDATA 4300 User Manual

Page 85: Step 7, Step 8

Advertising
background image

Maintenance Analysis Procedures

3-21

Maintenence Analysis Procedures

6

A loopback (wrap) plug is connected to the port with no diagnostic
running. Remove the plug from the port receptacle. If directed by the
customer, connect a fiber-optic jumper cable attaching a device to the
product.

If the port is operational with no device attached, both LEDs
adjacent to the port extinguish and the port state is No Light.

If the port is operational with a device attached, the blue/green
LED illuminates, the amber LED extinguishes, and the port state
is Online.

Was the maintenance action successful?

NO

YES

The product port is operational. Exit MAP.

Contact the next level of support. Exit MAP.

7

An ISL connection is not allowed because E_Port capability is
disabled. Install the full-fabric PFE key to enable E_port capability.
Refer to

Install PFE Keys (Optional)

.

Exit MAP.

8

The connection timed out because of an unresponsive device or an
ISL security violation (authorization failure reject). Check port status
and clean fiber-optic components.

a. Inform the customer the port will be blocked. Ensure the system

administrator quiesces Fibre Channel frame traffic and sets
attached devices offline.

b. Block the port. Refer to

Block or Unblock a Port

.

c. Clean fiber-optic connectors. Refer to

Clean Fiber-Optic

Components

.

d. Unblock the port. Refer to

Block or Unblock a Port

.

e. Monitor port operation for approximately five minutes.

Was the maintenance action successful?

NO

YES

The product port is operational. Exit MAP.

Advertising