McDATA Sphereon 4300 Fabric Switch Installation and Service Manual

Maintenence Analysis Procedures

2

The power supply may be disconnected or failed. Verify connection to
facility power.

a. Ensure the AC power cord is connected to the rear of the switch

and a facility power receptacle. If not, connect the power cord as
directed by the customer.

b. Ensure facility circuit breakers are on. If not, ask the customer to

set breakers on.

c. Ensure the AC power cord is not damaged. If damaged, replace

the cord.

Was the maintenance action successful?

NO

YES

The product is operational. Exit MAP.

A power supply failure is indicated. Replace the switch. Exit MAP.

MAP 0200: POST Failure Analysis

This MAP describes fault isolation for a POST failure. The failure
indicator is event code 400 or 411 observed at the Event Log.

1

Table 3-4

lists event codes, explanations, and MAP steps.

2

As indicated by event code 400, POST/IPL diagnostics detected a
FRU failure.

a. At the Event Log, examine the first two bytes of event data.

Table 3-4

MAP 200 Event Codes

Event
Code

Explanation

Action

400

Power-up diagnostic failure.

Go to

step 2

.

411

Firmware fault.

Go to

step 3

.