O to, Step 10, Step 11 – McDATA 4300 User Manual

Page 86: Go to

Advertising
background image

3-22

McDATA Sphereon 4300 Fabric Switch Installation and Service Manual

Maintenence Analysis Procedures

9

Inspect and service host bus adapters (HBAs).

Was the maintenance action successful?

NO

YES

The product port is operational. Exit MAP.

Contact the next level of support. Exit MAP.

10

A connection is not allowed because of a switch binding or exchange
security attribute (ESA) feature mismatch. Switch binding parameters
must be compatible for both fabric elements. At the EFCM Basic
Edition interface, ensure switch binding is enabled, the connection
policy is compatible, and switch membership lists are compatible for
both elements. Refer to the McDATA EFCM Basic Edition User
Manual
(620-000240) for instructions.

Was the maintenance action successful?

NO

YES

The product port is operational. Exit MAP.

Contact the next level of support. Exit MAP.

11

A connection is not allowed because of a fabric binding mismatch.
Fabric membership lists must be compatible for both elements. At the
EFCM Basic Edition interface, ensure fabric binding is enabled and
fabric membership lists are compatible for both elements. Refer to the
McDATA EFCM Basic Edition User Manual (620-000240) for
instructions.

Was the maintenance action successful?

NO

YES

The product port is operational. Exit MAP.

Contact the next level of support. Exit MAP.

Advertising