Event Code Tables

A-5

Event Code Tables

Event Code: 062

Message:

Maximum interswitch hop count exceeded.

Severity:

Informational.

Explanation:

Fabric controller software detected a path to a director or switch that traverses more than seven interswitch links
(hops). This may result in Fibre Channel frames persisting in the fabric longer than timeout values allow.

Action:

Reconfigure the fabric so the path between any two switches traverses seven or less ISLs.

Event Data:

Byte 0 = domain ID of the director or switch more than seven hops away.

Distribution:

Product

Management Server

Host

EFCM Basic

Event Log

System

Error LED

Event Log

E-Mail

Call-Home

Sense Info

Link Incident

Log

Event Code: 063

Message:

Remote switch has too many ISLs.

Severity:

Major.

Explanation:

The director or switch with domain ID indicated in the event data has too many ISLs attached and is unreachable
from this switch.

Action:

Reduce the ISLs on the indicated director or switch to a number within limits specified.

Event Data:

Byte 0 = domain ID of the director or switch with too many ISLs.

Distribution:

Product

Management Server

Host

EFCM Basic

Event Log

System

Error LED

Event Log

E-Mail

Call-Home

Sense Info

Link Incident

Log