S3F80JB

BASIC TIMER and TIMER 0

10-1

10

BASIC TIMER and TIMER 0

OVERVIEW

The S3F80JB has two default timers: the 8-bit basic timer and the 8-bit general-purpose timer/counter.
The 8-bit timer/counter is called timer 0.

BASIC TIMER (BT)

You can use the basic timer (BT) in two different ways:

— As a watch-dog timer to provide an automatic reset mechanism in the event of a system malfunction

— To signal the end of the required oscillation stabilization interval after a reset or a Stop mode release.

The functional components of the basic timer block are:

— Clock frequency divider (f

OSC

divided by 4096, 1024 or 128) with multiplexer

— 8-bit basic timer counter, BTCNT (FDH, Set 1, Bank0, Read-only)

— Basic timer control register, BTCON (D3H, Set 1, Bank0, R/W)

TIMER 0

Timer 0 has three operating modes, one of which you select using the appropriate T0CON setting:

— Interval timer mode

— Capture input mode with a rising or falling edge trigger at the P3.0 pin

— PWM

mode

Timer 0 has the following functional components:

— Clock frequency divider (f

OSC

divided by 4096, 256 or 8) with multiplexer

— External clock input pin (T0CK)

8-bit timer 0 counter (T0CNT), 8-bit comparator, and 8-bit reference data register (T0DATA)

— I/O pins for capture input (T0CAP) or match output

— Timer 0 overflow interrupt (IRQ0, vector FAH) and match/capture interrupt (IRQ0, vector FCH) generation

— Timer 0 control register, T0CON (D2H, Set 1, Bank0, R/W)

NOTE

The CPU clock should be faster than basic timer clock and timer 0 clock.