BASIC TIMER and TIMER 0

10-11

PROGRAMMING TIP — Programming Timer 0

This sample program sets timer 0 to interval timer mode, sets the frequency of the oscillator clock, and
determines the execution sequence which follows a timer 0 interrupt. The program parameters are as follows:

— Timer 0 is used in interval mode; the timer interval is set to 4 milliseconds

— Oscillation

frequency is 6 MHz

— General register 60H (page 0)

→ 60H + 61H + 62H + 63H + 64H (page 0) is executed after a timer 0 interrupt


VECTOR 00FAH,T0OVER

; Timer 0 overflow interrupt

VECTOR 00FCH ,T0INT

; Timer 0 match/capture interrupt


ORG

0100H

RESET: DI

;

Disable

all

interrupts

LD BTCON,#0AAH

;

Disable

the

watchdog

timer

LD CLKCON,#18H

;

Select

non-divided

clock

CLR SYM

;

Disable

global

and

fast

interrupts

CLR

SPL

; Stack pointer low byte

→ "0"

; Stack area starts at 0FFH

LD T0CON,#4BH

;

Write

‘00100101B’

;

Input

clock

is

f

OSC

/256

;

Interval

timer

mode

;

Enable

the

timer

0

interrupt

;

Disable

the

timer

0

overflow

interrupt

LD T0DATA,#5DH

;

Set

timer interval to 4 milliseconds

;

(6

MHz/256)

÷ (93 + 1) = 0.25 kHz (4 ms)


SRP #0C0H

;

Set

register

pointer

→ 0C0H

EI

;

Enable

interrupts

T0INT:

PUSH RP0

; Save RP0 to stack

SRP0

#60H

;

RP0

← 60H

INC R0

;

R0

← R0 + 1

ADD R2,R0

;

R2

← R2 + R0

ADC R3,R2

;

R3

← R3 + R2 + Carry

ADC R4,R0

;

R4

← R4 + R0 + Carry

(Continued

on

next

page)