Samsung S3F80JB User Manual

Page 333

Advertising
background image

DEVELOPMENT TOOLS DATA

S3F80JB

20-4

Table 20-2. Default Setting of the Jumper in S3F80JB Target Board

JP# Description 1-2

connection 2-3

connection

Setting

S1

Target board power source

Open-ice power

Join 1-2

JP1

Target board mode selection H: Main-Mode

L: EVA-Mode

Join 2-3

JP2

Operation Mode

H: User Mode

L: Test-Mode

Join 1-2

JP3

MDS version

SMDS2

SMDS2+

Join 2-3

JP5 Board

peripheral

power

connection

Board peripheral power connection

Connect

JP6

When supplied 5V in target
board, generation of 3.3V
using regulator.

In case of selection 3.3V
between open-ice powers,
connect core without a step
of regulation.

In case of selection 5V
between open-ice powers,
connect regulator to
generate 3.3V

Join 2-3

JP8

80JB V

DD

power connection 80JB V

DD

power connection

Connect

JP10

Clock source selection

When using the internal clock source which is generated
from OPENice-i500, join connector 2-3 and 4-5 pin. If
user wants to use the external clock source like a crystal,
user should change the jumper setting from 1-2 to 5-6
and connect Y1 to an external clock source.

JP11 Regulator

3.3

Volt-Out

connection

Connection between regulator out voltage and 80JB’s
Power V

DD

when using the regulator. When debugging

with Openice-i500, JP11 don’t need to be connect.

SW2

Smart option at address 3EH Dip switch for smart option. These 1byte are mapped

address 3EH for special function. Refer to the page 2-3.

SW3

Smart option at address 3FH Dip switch for smart option. These 1byte are mapped

address 3FH for special function. Refer to the page 2-3.

Y1

External clock source

Connecting point for external clock source like a crystal.

J3

Header for flash serial
programming signals

To program an internal flash, connect the signals with
flash writer tool.

J3

To

User_Vcc

Target System is supplied
V

DD

Target Board is not supplied
V

DD

to Target System.

Target Board is supplied
V

DD

to Target System.

Join 2-3

NOTE: S3F80JB Target board consists of 74HC11N, regulator and other components. In case of 74HC11N, typical

operating voltage is 5V. So 80jb target board includes a regulator for 3.3V generation. As you know, S3F80JB typical

operating voltage is 3.3V. Although open-i500 supports 3.3 V for target board ‘s power source, we recommend that

you connect jumper of open-i500 power source to 5V. Check the interface board’s jumper status between emulator

and target board.

– nRESET

LED

This LED is OFF when the Reset switch is ON.

– IDLE

LED

This is LED is ON when the evaluation chip (S3E80JB) is in idle mode.

– STOP

LED

This LED is ON when the evalution chip (S3E80JB) is in stop mode.

Advertising