S3F80JB

TIMER 2

13-1

13

TIMER

2

OVERVIEW

The S3F80JB microcontroller has a 16-bit timer/counter called Timer 2 (T2). For universal remote controller
applications, timer 2 can be used to generate the envelope pattern for the remote controller signal. Timer 2 has
the following components:

— One control register, T2CON (E8H, Set 1, Bank1, R/W)

— Two 8-bit counter registers, T2CNTH and T2CNTL (E4H and E5H, Set1, Bank1, Read only)

— Two 8-bit reference data registers, T2DATAH and T2DATAL (E6H and E7H, Set 1, Bank1, R/W)

— One

16-bit

comparator

You can select one of the following clock sources as the timer 2 clock:

— Oscillator

frequency

(f

OSC

) divided by 4, 8, or 16

— Internal clock input from the counter A module (counter A flip/flop output)

You can use Timer 2 in three ways:

— As a normal free run counter, generating a timer 2 overflow interrupt (IRQ3, vector F0H) at programmed time

intervals.

— To generate a timer 2 match interrupt (IRQ3, vector F2H) when the 16-bit timer 2 count value matches the

16-bit value written to the reference data registers.

— To generate a timer 2 capture interrupt (IRQ3, vector F2H) when a triggering condition exists at the P3.2 pin

for 44 package; at the P3.0 for 32 package (You can select a rising edge, a falling edge, or both edges as the
trigger).

In the S3F80JB interrupt structure, the timer 2 overflow interrupt has higher priority than the timer 2 match or
capture interrupt.

NOTE

The CPU clock should be faster than timer 2 clock.