Seiko Instruments SII Black-and-White Raster Plotter LP-1020 User Manual

Page 239

Advertising
background image

14-23

▼When an error message appears

Chapter 14 Troubleshooting

Error

code

Printed error memo

Description

Measure

0305

W SPOOL OVERFLOW

The spool memory overflows.

I n s t a l l o p t i o n a l H D D , o r

specify the CENTERING =
OFF if the device is used with

the CENTERING = ON.

0306

W POLYGON OVERFLOW

Polygon buffer overflow error
occurred.

Correct erroneous part at the
computer side. (Polygon buffer
upper limit: 106600 points)

0307

to

0313

W PDL ERR 307 to
W PDL ERR 313

Program warning

If the error is reproducible and the
print result is poor, the software
must be upgraded to the latest
version. Please notify your dealer or
our service center of the displayed
error message and error condition.

0314

W DATA IGNORED

Data is ignored, because there
is no effective plotting data.

Check the computer side if
e f f e c t i v e p l o t t i n g d a t a i s
transferred.

0400

W RASTER_DECODE_ERR

The format of the compressed
raster data is erroneous.

Check the computer side if the

f o r m a t o f t h e c o m p r e s s e d
raster data is correct.

0401

W RASTER_FORMAT_ERR

There is no raster data of the

size specified by the data.

Check the computer side if
data is correct.

0500

to

0505

- (No error memo)

Program warning

If the error is reproducible and the
print result is poor, the software
must be upgraded to the latest
version. Please notify your dealer or
our service center of the displayed
error message and error condition.

0600

W FORMATERROR

TIFF data is erroneous. Or,
the plotting failed due to an

omission of essential tag.

Correct erroneous part at the
computer side.

0601

W # OF PARAM. ERROR

The number of parameters of
TIFF data tag is wrong.

0602

W PARAM._RANGE_ERR

The parameter value of TIFF data
tag exceeds the supported range.

0603

- (No error memo)

Data is ignored, because there
is no effective plotting data in
TIFF data.

Check the computer side if
e f f e c t i v e p l o t t i n g d a t a i s
transferred.

0700

- (No error memo)

The plotting failed due to an

omission of essential record in
the CALS format.

Correct erroneous part at the
computer side.

Advertising