TROUBLESHOOTING & REPAIR

F-74

F-74

POWER WAVE 455M/MSTT

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

CURRENT
TRANSDUCER

P90

1234

RESISTOR
ASSEMBLY

STT OUTPUT
TERMINAL
(TOP RIGHT)

FIGURE F.25 – STT CURRENT TRANSDUCER REMOVAL AND REPLACEMENT PROCEDURE

STT CURRENT TRANSDUCER

REMOVAL AND PLACEMENT (CONTINUED)

REMOVAL PROCEDURE

1. Remove input power to the Power Wave

455.

2. Using the 3/8” nut driver, remove the case

top and right side.

3. Perform the Capacitor Discharge proce-

dure.

4. Using the wire cutters, cut all cable ties to

the transducer lead harness. Unplug the
harness and swing it aside.

5. Label and remove the leads to the resistor

assembly. See Figure F.25. Using the
5/16” socket wrench, extension and univer-
sal adapter, remove the resistor assembly.
It may be necessary to remove the plastic
high voltage protection shield. (Use the
3/8” nut driver.) It may also be necessary to
use a 5/16” open end wrench to remove the
inside screws. Carefully swing the resistor
assembly aside.