Troubleshooting & repair, Switch board test (continued) – Lincoln Electric POWER WAVE SVM173-A User Manual

Page 58

Advertising
background image

TROUBLESHOOTING & REPAIR

F-12

F-12

POWER WAVE 455M/MSTT

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Section

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

Retur

n

to

Master

TOC

19C

19D

RECONNECT
SWITCHES

FIGURE F.2 – RECONNECT SWITCHES

SWITCH BOARD TEST (CONTINUED)

TEST PROCEDURE

1. Remove input power to the Power Wave

455M.

2. Perform

the

Capacitor

Discharge

Procedure.

3. Locate label and remove leads 19C and 19D

from the reconnect switches with the 3/8”

wrench. Note lead placement for reassem-

bly. Clear leads. Refer to Figure F.2.

4. Using the Analog ohmmeter, perform the following

resistance tests. Refer to Figure F.3 for the test
points. Any readings below 100 ohms can be con-

sidered a short circuit. However, readings usually

are below 30 ohms.

Check 11/12 to -20 and 11/12 to +19

Check 13/14 to -20 and +19 to 13/14

5. If any test fails isolate the PC board and

retest, if board still fails, replace switch

board.

See Switch Board Removal and

Replacement.

6. If the switch board tests are OK, check the

molex pin connections and associated wiring

from the switch boards to the control board.

See the Wiring Diagram.

Advertising