background image

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-888-935-3877.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

OUTPUT PROBLEMS

The machine is dead—no lights—
no output—the machine appears to
be off.

1. Make certain the input power

switch SW1 is in the ON posi-
tion.

2. Check the main input fuses (or

breakers). If open, replace or
reset.

3. Check the 6 amp CB4 breaker

located in the reconnect area.
Reset if tripped.

4.

Make certain the reconnect
panel is configured correctly for
the applied input voltage.

1. Check the input power switch

SW1 for proper operation. Also
check the associated leads for
loose or faulty connections.
See the Wiring Diagram.

2. Check circuit breaker CB4 for

proper operation.

3. Perform the

DC Bus Board

Test.

4. The power board rectifier may

be faulty. Check rectifier and
associated wiring. See the
Wiring Diagram

5. Perform the Power Board Test.

6. Perform the T1 Auxiliary

Transformer Test.

7. The Control Board may be

faulty.

F-5

F-5

TROUBLESHOOTING & REPAIR

POWER WAVE 455M/MSTT