TROUBLESHOOTING & REPAIR

F-20

F-20

POWER WAVE 455M/MSTT

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

INPUT
CONTACTOR

601

X4

FIGURE F.5 – INPUT CONTACTOR COIL

INPUT CONTACTOR TEST (CONTINUED)

TEST PROCEDURE

1. Remove input power to the Power Wave

455.

2. Using the 3/8” nut driver, remove the input

access panel and case top.

3. Locate, mark, and remove the two leads

(601, X4) that are connected to the input
contactor coil. Refer to Figure F.5.

4. Using the external 24 VAC supply, apply 24

VAC to the terminals of the input contactor
coil. If the contactor does NOT activate, the
input contactor is faulty. Replace.