TROUBLESHOOTING & REPAIR

F-28

F-28

POWER WAVE 455M/MSTT

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

J42

J41

J43

4 5 6

3 4

7 8 9 10 11 12

J42

J41

J43

1 2 3

1 2

1 2 3 4 5 6

FIGURE F.8 – POWER BOARD TEST

POWER BOARD TEST (CONTINUED)

TEST PROCEDURE

1. Remove input power to the Power Wave

455M.

2. Using the 3/8” nut driver, remove the case

top.

3. Perform

the

Capacitor Discharge

Procedure.

4. Locate the Power Board and plugs J42 and

J43. Do not remove plugs or leads from
the Power Board
. Refer to Figure F.8.

5. Carefully apply input power to the Power

Wave 455M.

ELECTRIC SHOCK can kill.

High voltage is present when
input power is applied to the
machine.

6. Turn on the Power Wave 455M. Carefully

test for the correct voltages at the Power
Board according to Table F.3.

7. If either of the 40 VDC voltages is low or not

present at plug J41, perform the DC Bus
PC Board Test
. See the Wiring Diagram. If
indicated, perform the T1 Auxiliary
Transformer Test.

8. If any of the DC voltages are low or not pre-

sent at plugs J42 and/or 43, the Power
Board may be faulty.

9. If power board is replaced, reassemble and

test machine.

WARNING