Troubleshooting & repair, Input board test (continued), Warning – Lincoln Electric POWER WAVE SVM173-A User Manual

Page 80

Advertising
background image

TROUBLESHOOTING & REPAIR

F-34

F-34

POWER WAVE 455M/MSTT

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

INPUT BOARD TEST(CONTINUED)

6. Remove input power to the Power Wave

455M. If any of the voltages are low or not
present, perform the Input Contactor Test.
If that checks out, the Input Board may by
faulty.

7. Reconnect lead X4 to the main input contac-

tor CR1 coil terminal.

8. Carefully apply the correct input voltage to

the Power Wave 455M.

ELECTRIC SHOCK can kill.

High voltage is present when
input power is applied to the
machine.

9. Turn on the Power Wave 455M. Check for

the presence of 24 VAC from lead X4 to
lead 601. See Figure F. 9. If the voltage
is not present, perform the Auxiliary
Transformer #1 Test.

9.

This 24 VAC is the coil voltage for main
input contactor CR1. It will normally be
present approximately 12 seconds after
input line switch (SW1) is activated.

10. When the test is completed, remove input

power from the Power Wave 455M.

11. Install the case top and reconnect cover

using the 3/8” nut driver.

WARNING