TROUBLESHOOTING & REPAIR

F-50

F-50

POWER WAVE 455M/MSTT

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

INPUT
CONTACTOR

601

X4

FAN MOTOR

LEADS

X3

X5

POWER BOARD

RECTIFIER BRIDGE

X1

X2

+

-

FIGURE F.16 – AUXILIARY TRANSFORMER NO. 1 TEST

AUXILIARY TRANSFORMER NO. 1 TEST (CONTINUED)

TEST PROCEDURE

1. Remove the main input power to the Power

Wave 455 machine.

2. Using the 3/8” nut driver, remove the case

top.

3. Perform the Capacitor Discharge proce-

dure.

4. Locate secondary leads X1 and X2 (at

power board rectifier bridge). Refer to
Figure F.16.

5. Locate secondary leads X3 and X5 (fan

motor leads).

6. Locate secondary lead X4 (at main contac-

tor).