POWER WAVE CURRENT TRANSDUCER TEST (CONTINUED)

TEST PROCEDURE

1. Remove input power to the Power Wave

455.

2. Using the 3/8” nut driver, remove the case

top and the control box cover.

3. Locate the Power Wave current transducer

leads at Control Board plug J8. See Figure
F.11.

4. Carefully apply input power to the Power

Wave 455.

ELECTRIC SHOCK can kill.

High voltage is present when
input power is applied to the
machine.

WARNING