Board according to table f.3, Troubleshooting & repair, Power board test (continued) – Lincoln Electric POWER WAVE SVM173-A User Manual

Page 75

Advertising
background image

POWER BOARD

CONNECTOR

PLUG J41

POWER BOARD

CONNECTOR

PLUG J42

POWER BOARD

CONNECTOR

PLUG J42

POWER BOARD

CONNECTOR

PLUG J42

POWER BOARD

CONNECTOR

PLUG J43

POWER BOARD

CONNECTOR

PLUG J43

POWER BOARD

CONNECTOR

PLUG J43

POWER BOARD

CONNECTOR

PLUG J41

POWER BOARD

CONNECTOR

PLUG J43

POWER BOARD

CONNECTOR

PLUG J43

CHECK 40 VDC

INPUT FROM

DC BUS BOARD

CHECK +15

VDC SUPPLY FROM

POWER BOARD

CHECK +5 VDC

SUPPLY FROM

POWER BOARD

CHECK -15 VDC

SUPPLY FROM

POWER BOARD

CHECK +5 VDC

ARCLINK SUPPLY

FROM POWER BOARD

CHECK +5 VDC

“RS-232” SUPPLY

FROM POWER BOARD

CHECK +15 VDC

SPI SUPPLY FROM

POWER BOARD

CHECK +40 VDC

INPUT FROM

DC BUS BOARD

CHECK +5 VDC

SPI SUPPLY FROM

POWER BOARD

CHECK +20 VDC STT

SUPPLY FROM

POWER BOARD

2 (+)

1 (-)

1 (+)

5 (-)

3 (+)

5 (-)

2 (+)

5 (-)

5 (+)

10 (-)

4 (+)

9 (-)

6 (+)

11 (-)

4 (+)

3 (-)

3 (+)

12 (-)

7 (+)

1 (-)

477 (+)

475 (-)

225 (+)

222 (-)

221 (+)

222 (-)

222 (+)

223 (-)

274 (+)

273 (-)

226 (+)

228 (-)

266 (+)

267 (-)

478 (+)

476 (-)

268A (+)

262 (-)

345 (+)

346 (-)

38 – 42 VDC

+15 VDC

+5 VDC

-15 VDC

+5 VDC

+5 VDC

+15 VDC

38 – 42 VDC

+5 VDC

+20 VDC

TROUBLESHOOTING & REPAIR

F-29

F-29

POWER WAVE 455M/MSTT

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TABLE F.3 – POWER BOARD VOLTAGE CHECKS

POWER BOARD TEST (CONTINUED)

CHECK POINT

LOCATION

TEST

DESCRIPTION

CONNECTOR

PLUG PIN NO.

LEAD NO. OR

IDENTITY

NORMAL

ACCEPTABLE

VOLTAGE

READING

475

477

225

222

221

222

223

222

273

274

228

226

267

266

476

478

262

268A

345

346

Advertising