VOLTAGE SENSING

The best arc performance occurs when the Power
Wave has accurate data about the arc conditions.
Depending upon the process, inductance within the
electrode and work lead cables can influence the volt-
age apparent at the terminals of the welder. Voltage
sense leads improve the accuracy of the arc conditions
and can have a dramatic effect on performance.

If the voltage sensing is enabled but the sense leads
are missing or improperly connected, extremely high
welding outputs may occur.

Do not tightly bundle the work sense lead to the work
lead.

The sense leads connect to the Power Wave at the
four-pin connector located underneath the output ter-
minal cover. Lead 67 senses electrode voltage. Lead
21 senses work voltage.

Enable the voltage sense leads as follows:

TABLE A.2

Process

Electrode Voltage

Work Voltage

Sensing 67 lead *

Sensing 21 lead

GMAW

67 lead required

21 lead optional

GMAW-P

67 lead required

21 lead optional

FCAW

67 lead required

21 lead optional

STT

67 lead required

21 lead required

GTAW

Voltage sense at

Voltage sense at

terminals

terminals

SAW

67 lead required

21 lead optional

* The electrode voltage 67 sense lead is integral to the con-

trol cable to the wire feeder.

A-8

A-8

INSTALLATION

POWER WAVE 455M/MSTT

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

POWER

WA

VE 455/R

I ON

O OFF

POWER

WA

VE 455/R

FIGURE A.3 – DIP SWITCH LOCATION

CAUTION

REMOVE
FRONT
COVER

WIRE FEED
HEAD BOARD
ON RIGHT

CONTROL
BOARD
ON LEFT