TROUBLESHOOTING & REPAIR

F-45

F-45

POWER WAVE 455M/MSTT

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

RECEPTACLE
S7

STT

POWER

WAVE

FIGURE F.14 – RECEPTACLE S7 TRIGGERED

STT CURRENT TRANSDUCER TEST (CONTINUED)

5. Turn on the Power Wave 455M. Check for

the correct DC supply voltage to the current
transducer at plug J8.

A. Pin 8 (lead 812+) to pin 7 (lead 816-)

should read +15 VDC.

B. Pin 4 (lead 813-) to pin 7 (lead 816+)

should read -15 VDC.

If the DC supply voltages are not present,
the control board may be faulty.

6. If both of the supply voltages are low or

missing, check the associated leads
between plug J8 and current transducer plug
P90 and the Control Board.

NOTE: The machine can be triggered by

jumpering pin 1 to pin 2 at receptacle
S7. See Figure F. 14.

7. With the Power Wave 455M triggered, check

the feedback voltage from the current trans-
ducer. The current feedback voltage can be
read at plug J8 on the Control Board.

A. Pin 5 (lead 811) to pin 7 (lead 816)

should read 0.4 VDC (machine loaded
to 50 amps).