Installation, Caution – Lincoln Electric POWER WAVE SVM173-A User Manual

Page 15

Advertising
background image

WORK VOLTAGE SENSING

The Power Wave is shipped from the factory with the
work sense lead enabled.

For processes requiring work voltage sensing, connect
the (21) work voltage sense lead from the Power Wave
to the work. Attach the sense lead to the work as close
to the weld as practical. To enable the work voltage
sensing in the Power Wave, refer to the section DIP
SWITCH SETTINGS AND LOCATIONS.

ELECTRODE VOLTAGE SENSING

Enabling or disabling electrode voltage sensing is auto-
matically configured through software. Electrode sense
lead 67 must be connected at the wire feeder.

POWER WAVE / POWER FEED WIRE
FEEDER INTERCONNECTIONS

Connect the control cable between the power source
and wire feeder. The wire feeder connection on the
robotic Power Wave is located under the spring loaded
output cover, near the bottom of the case front. The
control cable is keyed and polarized to prevent improp-
er connection.

For convenience sake, the electrode and control
cables can be routed behind the left or right strain
reliefs (under the spring loaded output cover), and
along the channels formed into the base of the Power
Wave, out the back of the channels, and then to the
wire feeder.

Output connections on some Power Waves are made
via 1/2-13 threaded output terminals located beneath
the spring-loaded output cover at the bottom of the
case front. On machines which carry the CE mark, out-
put connections are made via Twist-Mate receptacles,
also located beneath the spring-loaded output cover at
the bottom of the case front.

A work lead must be run from the negative (-) power
source output connection to the work piece. The work
piece connection must be firm and secure, especially if
pulse welding is planned.

Excessive voltage drops at the work piece connection
often result in unsatisfactory pulse welding perfor-
mance.

CONTROL CABLE SPECIFICATIONS

It is recommended that genuine Lincoln control cables
be used at all times. Lincoln cables are specifically
designed for the communication and power needs of
the Power Wave / Power Feed system.

The use of non-standard cables, especially in lengths
greater than 25 feet, can lead to communication prob-
lems (system shutdowns), poor motor acceleration
(poor arc starting) and low wire driving force (wire feed-
ing problems).

Lincoln control cables are copper 22 conductor cable in
a SO-type rubber jacket.

EXTERNAL I/O CONNECTOR

The Power Wave is equipped with a port for making sim-
ple input signal connections. The port is divided into
three groups: Trigger group, Cold Inch Group and
Shutdown Group. Because the Power Wave is a “slave”
on the DeviceNet network, the Trigger and Cold Inch
Groups are disabled when the DeviceNet/Gateway is
active.

The Shutdown Group is always enabled. Shutdown 2 is
used for signaling low flow in the water cooler. Unused
shutdowns must be jumpered. Machines from the fac-
tory come with the shutdowns already jumpered. (See
Figure A.4)

A-9

A-9

INSTALLATION

POWER WAVE 455M/MSTT

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

CAUTION

CAUTION

D

E

F

1

2

3

4

5

6

78

910 11 12

G

H

I

A

B

C

+15

VDC f

or

T

rigger Group

Tr

igger Input

Dual Procedure Input

4 Step Input

+15

VDC f

or Cold Inch Group

Cold Inch F

orw

ard

Cold Inch Re

v

erse

Gas Purge Input

+15 f

or shutdo

wn g

roup

Shutdo

wn1 input

Shutdo

wn2 input

Reser

v

ed f

or future use

FIGURE A.4 – INPUT PORT CONNECTIONS