Symptoms, Troubleshooting & repair, Caution – Lincoln Electric POWER WAVE SVM173-A User Manual

Page 50

Advertising
background image

Observe Safety Guidelines

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con-
tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call
1-888-935-3877.

PROBLEMS
(SYMPTOMS)

POSSIBLE AREAS OF
MISADJUSTMENT(S)

RECOMMENDED
COURSE OF ACTION

OUTPUT PROBLEMS

The input fuses repeatedly fail or
the input circuit breakers keep trip-
ping.

1. Make certain the fuses or break-

ers are properly sized.

2.

Make certain the reconnect
panel is configured properly for
the applied voltage.

3. The welding procedure may be

drawing too much input current
or the duty cycle may be too
high. Reduce the welding cur-
rent and /or reduce the duty
cycle.

1. Check the reconnect switches

and associated wiring. See the
Wiring Diagram.

2. Perform the Input Rectifier

Test.

3. Perform the Switch Board

Test.

4. Perform the Input Contactor

Test.

F-4

F-4

TROUBLESHOOTING & REPAIR

POWER WAVE 455M/MSTT

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC