TROUBLESHOOTING & REPAIR

F-32

F-32

POWER WAVE 455M/MSTT

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

INPUT
CONTACTOR

601

X4

J60

J61

6 7 8 9 10

J61

1 2 3 4

5 6 7 8

1 2 3 4 5

J60

FIGURE F.9 – INPUT CONTACTOR CR1

INPUT BOARD TEST (CONTINUED)

TEST PROCEDURE

1. Remove input power to the Power Wave

455M.

2. Using the 3/8” nut driver, remove the case

top, and input access cover.

3. Remove lead X4 from the coil terminal of

main input contactor CR1. Insulate lead X4.
Refer to Figure F.9.

4. Carefully apply input power to the Power

Wave 455M.

ELECTRIC SHOCK can kill.

High voltage is present when
input power is applied to the
machine.

5. Turn on the Power Wave 455M. Carefully

test for the correct voltages according to
Table F.4.

WARNING