Maintenance

4-2

3160-A2-GB21-80

March 1999

3. View the results of the last power-up self-test. If no problems were found

during power-up, the following message appears.

F1

STest Health:
Passed

F2

F3

Table 4-1.

Self-Test Health Messages

Message

Description

Passed

No problems were found during power-up.

CPU fail

The central processing unit failed internal testing.

Device fail

One or more of the unit’s integrated circuit chips failed to pass
internal device level testing.

B8ZS/LOS fail

The unit failed to encode data properly or to detect Loss Of
Signal.

Alarm fail

The unit failed to transmit AIS or to detect an Yellow alarm.

Memory fail

The unit failed program checksum verification.

LCD fail

The front panel liquid crystal display (LCD) failed.

NET T1 fail

The unit failed to internally loop data on the network T1 circuit.

DTE T1 fail

The unit failed to internally loop data on the DTE T1 (DSX-1)
circuit.

DSU fail

The unit failed to internally loop data on the DSU.

DSU Port

n fail

Port’s integrated circuitry failed to pass device internal testing.

Modem fail

Unit failed to internally loop data through the modem circuit.

Unknown Exp Dev

The unit is not able to recognize the expansion device
connected to the main circuit card.

Failure

xxxxxxxx

An 8-digit hexadecimal failure code is provided for service
personnel.